Programming Guide for DM3058
Function:
The command queries and sets upper value in P/F calculation.
Parameters:
Name
Type
Range of Values
Default
<value>
consecutive real number
See table 3-11
0
Explanations:
:calculate:limit:upper?: Queriy the upper value of P/F operation.
:calculate:limit:upper<value>: Set
the upper value of P/F calculation. The
default range of <range> please refer to Table 3-11.
Return Format:
The query returns current upper value.
18. :calculate:limit:state
Command Format:
:calculate: limit:state?
:calculate: limit:state{ON|OFF}
Function:
The command queries the enable state of P/F operation.
Explanations:
:calculate: limit:state?: Enable or disable P/F operation.
:calculate: limit:state{ON|OFF}: Set the state of P/F operation.
Return Format:
The query returns the enable state of P/F operation: ON or OFF that denotes
turning P/F operation on or off.
.
Example:
Disable P/F operation:
:calculate:limit:stateOFF