Rigol DM3058 Specifikace Strana 246

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 264
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 245
RIGOL
Programming Guide for DM3058
7-8
Example 4: dB Measurement
Purpose: Use commands to perform dB measurement.
dB measurement unit which is frequently used in electrician, wireless, mechanics,
oscillatory surge, mechanical power, acoustics and some other fields.
The programming steps——RIGOL Commands:
0 *RST /*Reset the instrument for preparing measurement*/
1 cmdsetrigol /*Select RIGOL commands*/
2 *IDN? /*Query equipment ID to confirm if the
instrument works normally*/
3 /*Connect the test leads under AC voltage measure mode*/
4 :function:voltage:AC /*Enable AC voltage measuring function*/
5 :measure:voltage:AC<range> /*Set the measuring range*/
6 :calculate:functionDB /*Enable dB measuering function*/
7 :calculate:DB:reference<value> /*Set the dB setting value*/
8 :calculate:DB? /*Query the measured value*/
9 /*Return value*/
Zobrazit stránku 245
1 2 ... 241 242 243 244 245 246 247 248 249 250 251 ... 263 264

Komentáře k této Příručce

Žádné komentáře