Example 10: Triggering on a Digital Signal
The triggering way, especially to the Digital Signal, which the Pattern and Duration
triggering are use for to carry on when triggering system was being used.
The two triggering ways are only allowed to a digital signal.
Pattern
Do the steps as following:
1. Press the MENU key in the triggering control area to see the trigger menu
2. Press Mode to select Pattern mode
3. Turn (
))knob to select the channel you want to set
4. Press Code to set Code Setting (H, L, X,
, or )
5. Press Sweep to select trigger mode to: Auto, Normal, or Single
6. Press Set Up to adjust the Holdoff time.