RIGOL 2 Command System
2-158 DS2000 Programming Guide
2-158
:CURSor:TRACk:SOURce2
Syntax
:CURSor:TRACk:SOURce2 <source>
:CURSor:TRACk:SOURce2?
Description
Set the measurement source of cursor B in track cursor measurement.
Query the current measurement source of cursor B in track cursor measurement.
Parameter
Name Type Range Default
<source> Discrete {CHANnel1|CHANnel2|MATH|NONE} CHANnel1
Note: only channels currently enabled can be selected as the channel source.
Explanation
CHANnel1, CHANnel2: select CH1 or CH2 as the measurement source of cursor B.
MATH: select the waveform of the math operation channel as the measurement
source of cursor B.
NONE: do not use cursor B.
Return Format
The query returns CHAN1, CHAN2, MATH or NONE.
Example
:CURSor:TRACk:SOURce2 CHANnel2
The query returns CHAN2.