Rigol DS1204B Specifikace Strana 48

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 152
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 47
RIGOL Command Systems
Programming Guide for DS1000B Series
2-36
VIDEO Trigger
1. :TRIGger:VIDEO:MODE
Command Format:
:TRIGger:VIDEO:MODE <mode>
:TRIGger:VIDEO:MODE?
Function:
The command sets the trigger sync mode as ODDfield, EVENfield, LINE or
ALLlines.
Returned Format:
The query returns ODD FIELD, EVEN FIELD, LINE or ALL LINES.
Example:
:TRIG:VIDEO:MODE EVEN Set the trigger sync mode as even field.
:TRIG:VIDEO:MODE? Return EVEN FIELD.
2. :TRIGger:VIDEO:POLarity
Command Format:
:TRIGger:VIDEO:POLarity {POSitive|NEGative}
:TRIGger:VIDEO:POLarity?
Function:
The command sets the video polarity as POSitive (it is applicable for the video
signal that the black level is low) or NEGative (the black level is high).
Returned Format:
The query returns POSITIVE or NEGATIVE.
Example:
:TRIG:VIDEO:POL POS Set the video polarity as positive.
:TRIG:VIDEO:POL? Return POSITIVE.
Zobrazit stránku 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 151 152

Komentáře k této Příručce

Žádné komentáře