Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-111
:TRIGger:WINDows:ALEVel
Syntax :TRIGger:WINDows:ALEVel <level>
:TRIGger:WINDows:ALEVel?
Description Set or query the trigger level upper limit in windows trigger. The unit is the same as the
current amplitude unit.
Parameter
Name
Type
Range
Default
<level> Real
(± 5 × VerticalScale from the screen center) OFFSet
2V
Explanation For VerticalScale, refer to :CHANnel<n>:SCALe. For OFFSet, refer
to :CHANnel<n>:OFFSet.
Return
Format
The query returns the trigger level upper limit in scientific notation.
Example
:TRIGger:WINDows:ALEVel 0.16 /*Set the trigger level upper limit to 160mV*/
:TRIGger:WINDows:ALEVel? /*The query returns 1.600000e-01*/
Related
Command
:CHANnel<n>:SCALe
:CHANnel<n>:OFFSet
:TRIGger:WINDows:BLEVel
Syntax :TRIGger:WINDows:BLEVel <level>
:TRIGger:WINDows:BLEVel?
Description Set or query the tigger level lower limit in windows trigger. The unit is the same as the
current amplitude unit.
Parameter
Name
Type
Range
Default
<level>
Real
(± 5 × VerticalScale from the screen center) OFFSet
0
Explanation For VerticalScale, refer to :CHANnel<n>:SCALe. For OFFSet, refer
to :CHANnel<n>:OFFSet.
Return
Format
The query returns the tigger level lower limit in scientific notation.
Example
:TRIGger:WINDows:BLEVel 0.05
Related
Command
:CHANnel<n>:SCALe
:CHANnel<n>:OFFSet